Projects/Completed

Lead-Free Solder
Testing for High Reliability
Project Number: S-01-EM-026

Completed in 2006


Potential Alternatives Report

A PAR identifies the baseline process; discusses the potential alternative technologies; identifies initial environmental, safety, and occupational health screening data; and documents the down-selection process. The alternatives selected for testing in accordance with the JTP are documented in this PAR.

The lead-free solder alloys agreed by the project stakeholders to be tested are as follows:

  • Stabilized Tin-copper (99.3Sn-0.7Cu+Ni(-0.05Ni)) for wave and manual soldering ·
  • Tin-silver-copper (95.5Sn-3.9Ag-0.6Cu) for wave, reflow and manual soldering ·
  • Tin-silver-copper-bismuth (92.3Sn-3.4Ag-1.0Cu-3.3Bi) for reflow and manual soldering.

These three alloys were selected based on a combination of their relative likelihood of meeting or exceeding the JTP requirements (based on prior test data), their physical processing characteristics, and their dominance in the solder market.

To view the PAR for for Validation of Alternatives to Eutectic Tin-Lead Solders used in Electronics Manufacturing and Repair, dated August 4, 2003, revised December 2, 2003 please click here.

Related Topics

Project Matrix and Points of Contact

Meeting and Teleconference Summaries

Presentations

Technology Survey

Potential Alternatives Report

Joint Test Protocol

Joint Test Report

Information Sheet

Related Links

Project Summary

 

This site last updated February 28, 2008.


Send all questions and comments to jgpp@ctc.com